International Clinical and Medical Case Reports Journal (ISSN: 2832-5788) | Volume 5, Issue 11 | Case Report | Open Access DOI
Giovanni Mosti*
Michela Piludu1, Simone Ugo Urso2, Paola Molinari3, Antonella Franceschelli4, Elena Calabria5, Martina Zuccaro6, Bianca Genovese7 and Giovanni Mosti8*
1General Surgeon, Aesthetic doctor, Private practice, Cagliari, Italy
2Aesthetic Doctor, Studio Medico 109 and Eco109, Zola Predosa (BO), Italy
3General Surgeon, Aesthetic Doctor, Private practice, Modena, Italy
4Aesthetic Doctor, Unicamillus International Medical University - Roma, Rome, Italy
5Doctor in Dental Science, School of Dentistry, Department of Health Sciences, Magna Graecia University, Catanzaro, Italy
6Aesthetic Doctor Private Practice, Latina, Italy
7Aesthetic doctor, Private Practice, Siracusa, Italy
8Aesthetic doctor, Private Practice, Lucca, Italy
*Correspondence to: Giovanni Mosti
Fulltext PDFBackground: Facial ultrasound became an essential tool in aesthetic medicine for anatomical assessment, vascular mapping, treatment planning, and complication management. Despite its growing adoption, it remains operator-dependent and often lacks a standardized scanning strategy. FacEcoFastÒ is a rapid, reproducible, clinically oriented ultrasound protocol that enables targeted evaluation of clinically relevant facial regions. Aim: describing the FacEcoFastÒ protocol assessing its feasibility and clinical applicability as a rapid, standardized method for high-frequency facial ultrasound in aesthetic medicine.
Methods: An evaluation of the FacEcoFast protocol was conducted in 463 consecutive patients undergoing facial ultrasound. The face was divided into four anatomical regions (lower third, midface, upper third, and nose), each examined at predefined scanning checkpoints using an 18 MHz to 20 MHz high-frequency linear probe. Feasibility, examination performance, and clinical indications are reported.
Results: FacEcoFast was successfully completed in all patients, demonstrating procedural feasibility. The midface, including the infraorbital and lower eyelid regions, was the most commonly evaluated anatomical area. Clinical indications included complication assessment (82%), pretreatment planning (12%), and post-treatment follow-up (6%). All predefined anatomical structures were identified, and diagnostic image quality was adequate in every examination. The mean examination time was 9 minutes (range 4 minutes to 20 minutes).
Conclusions: FacEcoFast offers a standardized and rapid approach to facial ultrasound. The protocol demonstrated complete anatomical visualization and integration into routine clinical practice, while reducing unnecessary scanning. By standardizing ultrasound assessment with predefined anatomical checkpoints, FacEcoFast may improve procedural safety, facilitate longitudinal follow-up, enhance physician training, and support broader implementation of facial ultrasound in aesthetic medicine.
Aesthetic medicine; Ultrasound examination; Face ultrasound; Standardized face ultrasound
Michela Piludu, Simone Ugo Urso, Paola Molinari, Antonella Franceschelli, Elena Calabria, Martina Zuccaro, Bianca Genovese and Giovanni Mosti. FacEcofast: Proposal of a Standardized Ultrasound Protocol for Facial Aesthetic Medicine. Int Clinc Med Case Rep Jour. 2026;5(11):1-12.